Serial number |
Model |
Name |
Specification range |
额定电压 |
1 |
ZAN-RVV |
Polyvinyl chloride insulated polyvinyl chloride sheath flame retardant class A refractory soft wire |
0.5-0.75mm2(2-3芯);0.75-2.5mm2(2-5芯) |
300/300V;300/500V |
1.5-10mm2(2-5芯);0.75-2.5mm2(6-10芯);0.5-1.0mm2(12-41芯);0.75+2.0mm2(2+E-38+E芯)
300/500V
1.5-10mm2(2-5芯);0.75-2.5mm2(6-10芯);0.5-1.0mm2(12-41芯);0.75+2.0mm2(2+E-38+E芯) |
300/500V |
2 |
ZAN-RVVP |
Polyvinyl chloride insulated polyvinyl chloride sheath braided shielded flame retardant class A refractory soft wire |
0.08-2.5mm2(1芯);0.08-4mm2(2芯);0.12-4mm2(3-12芯);0.12-0.4mm2(14、19、24芯);0.12-2.5mm2(16芯);0.12-0.5mm2(20、26芯); |
300/300V |
3 |
ZAN-BVV |
Polyvinyl chloride insulated polyvinyl chloride sheathed flame retardant class A refractory cable |
1.5-10mm2(2-5芯) |
300/500V |
4 |
ZAN-KVV |
Polyvinyl chloride insulated polyvinyl chloride sheath flame retardant class A fire-resistant control cable |
0.75-10mm2(2-10芯);0.75-6mm2(12-14芯);0.75-2.5mm2(16-61芯) |
450/750V |
5 |
ZAN-KVVR |
Polyvinyl chloride insulated polyvinyl chloride sheathed flame retardant class A controlled fire-resistant flexible cable |
0.75-10mm2(2-10芯);0.75-6mm2(12-14芯);0.75-2.5mm2(16-61芯) |
450/750V |
6 |
ZAN-KVVP |
Polyvinyl chloride insulated polyvinyl chloride sheath braided shielded flame retardant A refractory control cable |
0.75-10mm2(2-10芯);0.75-6mm2(12-14芯);0.75-2.5mm2(16-44芯) |
450/750V |
7 |
ZAN-KVVRP |
Polyvinyl chloride insulated polyvinyl chloride sheath braided shielded flame retardant A refractory controlled flexible cable |
0.75-10mm2(2-10芯);0.75-6mm2(12-14芯);0.75-2.5mm2(16-44芯) |
450/750V |
Product Code Description |
Z: flame retardant; ZA, ZB, ZC, ZD; V: polyvinyl chloride; N: fire resistance; K: control wire; R: soft wire and cable for connection; S: twisted pair; P: braided shielding; |
-
Flame-retardant multi-core sheathed cables/control cables have excellent flame-retardant performance. Flame-retardant cables are widely used in telephone exchanges and computer control centers, high-rise buildings, hotels, hospitals, libraries, gymnasiums, underground shopping malls, radio and television stations, chemical facilities, petroleum platforms, etc.
-
Conductor: stranded high purity oxygen-free bare copper wire.
Thermal Insulation Layer: High Temperature Resistant Synthetic Mica
Insulation: flame retardant polyvinyl chloride insulator at 70 C
Sheath: 70C flame retardant PVC sheath, color: (optional)
-
Physical and mechanical properties: the tensile strength of insulation is not less than 10.0 MPa, the elongation at break is not less than 150%; the tensile strength of sheath is not less than 12.0 MPa, and the elongation at break is not less than 100%.
Minimum bending radius: 10 x D, minimum bending diameter <12.5 MM at low temperature-15 C
Operating voltage: U. / U 300/300V, 300/500V, 450/750V
The flame-retardant performance of flame-retardant cables (wires) should be tested by GB1266.5-90 and IEC60332 bundles of wires and cables. The flame-retardant grades can be divided into four categories: A, B, C and D.
Temperature range: - 10 ~ + 70
-
Low halogen and high flame retardancy
ROHS environmentally friendly and REACH SVHC environmentally friendly PVC compound
High flame retardant and self-extinguishing performance of wire, extinguishing characteristics when off-fire.
It has the characteristics of acid and alkali resistance, oil resistance, moisture-proof and mildew-proof.
-
Editing...