分享按钮

Hello! Welcome to the official website of Shenzhen Lilutong Technology Industrial Co., Ltd.!

Single/Double Core Flame Retardant Environmental Protection PVC Wire

Advisory Service
  • Product Model, Production Range
  • Product Usage
  • Product Structure
  • Product Performance
  • Product Advantage (Selling Point)
  • Product Code Identification
  • Serial number Model Name Specification range Rated voltage
    1 ZA-BV PVC Insulated Flame Retardant Category A Fixed Wiring 1.5-70mm2 (1 core) 450/750V
    2 ZA-RV PVC Insulated Flame Retardant Class A Soft Wire 0.5-1.0 mm 2 (1 core); 1.5-185 mm 2 (1 core) 300/500V;450/750V
    3 ZA-RVS Polyvinyl chloride insulated flame retardant type A twisted pair wire 0.5-6 mm2 (2 cores) 300/300V
    Product Code Description Z: flame retardant; ZA, ZB, ZC, ZD; V: polyvinyl chloride; B: fixed laying cables (wires); R: connecting soft wires and soft cables; S: twisted pair type;
  • General purpose single core hard conductor sheathless wire, suitable for AC voltage 450/750V and below power devices, household appliances, instrumentation and telecommunications equipment for cable and wire. It can also be used as communication equipment and electronic transmission equipment such as electric control cabinet, distribution box, telephone exchange and other occasions. In view of the single-layer insulation structure, this cable can not be used as a power connection for external equipment (not as a mobile bending towline cable)

  • Conductor: high purity oxygen-free bare copper wire.
    Insulation: flame retardant polyvinyl chloride insulator at 70 C


  • ●Physical and mechanical properties: the tensile strength of insulation is not less than 10.0 MPa, the elongation at break is not less than 150%; the tensile strength of sheath is not less than 12.0 MPa, and the elongation at break is not less than 100%.
    ●The flame retardant performance of flame-retardant cables (wires) should pass the bundled wire and cable combustion tests of GB1266.5-90 and IEC60332. The flame retardant grade can be divided into four categories: A, B, C and D.
    ●working voltage: U。/U为 450/750、300/500、300/300V
    ●Minimum bending radius: (Series B) The allowable bending radius should be no less than 4D if the cable outer diameter (D) is less than 25MM; and the allowable bending radius should be no less than 6D if the cable outer diameter (D) is more than 25MM.
    ●Use temperature range:-10℃~+70℃
    ●Long-term allowable temperature of cable: - 105 type cable allowable working temperature should not exceed 105 other types of cable allowable working temperature should not exceed 70.

  • ●Low halogen and high flame retardancy
    ●Low halogen, high flame retardant properties have acid and alkali resistance, oil resistance, moisture resistance, mildew resistance and other characteristics.
    ● ROH Senvironmental protection、accord withREACH SVHC环保PVCRubber compound
    ●Wire has high flame retardancy, strong self-extinguishing property and extinguishing characteristic when it leaves fire.

  • Editing...

Copyright © 2018 Shenzhen Lilutong Technology Industrial Co., Ltd All rights reserved © Copying is prohibited without permission    ICP:粤ICP备11085524号
Technical Support: 南博网